BTM one Technical Data
Data Acquisition
Principle
Structured light
Light Source
Blue LED
Middle field of view
81.3 mm × 76.2 mm
Measurement range in z-direction
40 mm
Standoff distance
27 mm from the highest point of devicern
73 mm from glass measurement area
73 mm from glass measurement area
Depth Resolution (z)
6 μm
Point to point distance (x, y)
33 μm
Max. points per 3D point cloud
8.1 M
Data Acquisition time
0.1 s to 2.1 s, depending on scan mode
Export 3D data
~ 1 s
Hardware
Ingress Protection
IP54
Operating Conditions
Temperature: −10°C to 55°C
Humidity: 10% to 80% (non-condensing)
Humidity: 10% to 80% (non-condensing)
Storage Temperature
−40°C to 80°C
Dimensions (W × D × H)
152 mm × 152 mm × 175 mm
Weight
2.55 kg
Scanner Interface
USB 3.0
Power Supply
12 V DC, 5A, External power supply
Software
Supported Operating System
Windows 10/11 (64-bit)
Software
BTM Capture including Python API
Data Output
3D data as point cloud (.ply or .txt), x,y,z-map, Gridded Depthmap (as .tiff or .exr), 2Dgrayscale image (as .png)
Data Processing
Definition of ROI/mask, minimum/maximum filtering and standard deviation-based filtering, reprojection onto a best-fit reference plane for predominantly planar targets
SDK
BTM C++